Частотные преобразователи HYUNDAI N300 от 5.5 до 132 кВт

Новый N300 с функцией полного векторного контроля - один из самых мощных и компактных инверторов своего класса.Общепромышленное исполнение и и суперэкономичная серия для насосов и вентиляторов N300P
|
Model |
N300 |
N300 |
N300 |
N300 |
N300 |
N300 |
N300 |
|||
|
|
Applicable motor(kW) |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
| |
|
Rated current(A) |
11 |
15 |
22 |
29 |
37 |
43 |
57 |
| ||
|
Rated Capacity(KVA) |
8.2 |
11.2 |
16.5 |
21.7 |
27.7 |
32.2 |
42.6 |
| ||
|
Output Voltage(V) |
3 phase 380~480V |
| ||||||||
|
Output maximum frequency(Hz) |
400Hz |
| ||||||||
|
Input Power(V / Hz) |
3 pahse, 380~480VAC, 50/60Hz |
| ||||||||
|
Enclosure |
IP20 (NEMA1) |
| ||||||||
|
Control Characteristic |
Control method |
Line to line sine wave pulse-width modulation (PWM) control |
| |||||||
|
Voltage/Frequency Characteristic |
V/f control(Constant Torque, Reduction Torque) , V/f optionally variable (7 Point) |
| ||||||||
|
Output Frequency Range |
0.1~400Hz |
| ||||||||
|
Overload Rating |
120% for 60sec., 150% for 0.5sec. |
|||||||||
|
Acceleration/ Deceleration Time |
0.01~3600 sec |
| ||||||||
|
Braking Torque |
Regenerative |
130~150%(Discharge resistor applied), 10~20%(Capacitor feedback) |
||||||||
|
DC Braking |
Operating frequency(0~60Hz), operating time(0~60sec), operating voltage(0~100%) |
| ||||||||
|
External DC braking setting possible |
| |||||||||
|
Input Signals |
Analog |
0~10VDC, 4~20mA, -10~10VDC |
| |||||||
|
Digital |
Control panel |
|||||||||
|
Multispeed Selection |
Max. 16-stage (Bit command also available) |
| ||||||||
|
Protection Function |
Over current protection, overload protection, braking resistor overload, over voltage protection, EEPROM error, under-voltage error, CPU error, external trip, USP, ground fault, input over-voltage protection, inverter thermal trip, gate array error and |
| ||||||||
|
Other Function |
AVR function, V/f characteristic selection, accel/ decel curve selection, frequency upper/lower limit, PID control, frequency jump, accel./decel. curve selection, external frequency input bias start/end, jogging, retry after trip, restart after instantane, fuzzy accel/decel |
| ||||||||
|
Environment |
Ambient Temperature |
-10℃~50℃ / -20℃~65℃ |
| |||||||
|
Ambient Humidity / Installation Area |
90%RH or less (No condensation) / indoors (no corrosive gases or dust) |
| ||||||||
|
Altitude |
Altitude 1,000m or less |
| ||||||||
|
Model |
N300 |
N300 |
N300 |
N300 |
N300 |
N300 |
N300 |
N300 |
|||
|
|
Applicable motor(kW) |
37 |
45 |
55 |
75 |
90 |
110 |
132 |
160 |
| |
|
Rated current(A) |
70 |
85 |
105 |
135 |
160 |
195 |
230 |
295 |
| ||
|
Rated Capacity(KVA) |
52.4 |
63.6 |
78.5 |
101.0 |
119.7 |
145.9 |
172.0 |
220.7 |
| ||
|
Output Voltage(V) |
3 phase 380~480V |
| |||||||||
|
Output maximum frequency(Hz) |
400Hz |
| |||||||||
|
Input Power(V / Hz) |
3 pahse, 380~480VAC, 50/60Hz |
| |||||||||
|
Enclosure |
IP20 (NEMA1) |
| |||||||||
|
Control Characteristic |
Control method |
Line to line sine wave pulse-width modulation (PWM) control |
| ||||||||
|
Voltage/Frequency Characteristic |
V/f control(Constant Torque, Reduction Torque) , V/f optionally variable (7 Point) |
| |||||||||
|
Output Frequency Range |
0.1~400Hz |
| |||||||||
|
Overload Rating |
120% for 60sec., 150% for 0.5sec. |
||||||||||
|
Acceleration/ Deceleration Time |
0.01~3600 sec |
| |||||||||
|
Braking Torque |
Regenerative |
130~150%(Discharge resistor applied), 10~20%(Capacitor feedback) |
|||||||||
|
DC Braking |
Operating frequency(0~60Hz), operating time(0~60sec), operating voltage(0~100%) |
| |||||||||
|
External DC braking setting possible |
| ||||||||||
|
Input Signals |
Analog |
0~10VDC, 4~20mA, -10~10VDC |
| ||||||||
|
Digital |
Control panel |
||||||||||
|
Multispeed Selection |
Max. 16-stage (Bit command also available) |
| |||||||||
|
Protection Function |
Over current protection, overload protection, braking resistor overload, over voltage protection, EEPROM error, under-voltage error, CPU error, external trip, USP, ground fault, input over-voltage protection, inverter thermal trip, gate array error and |
| |||||||||
|
Other Function |
AVR function, V/f characteristic selection, accel/ decel curve selection, frequency upper/lower limit, PID control, frequency jump, accel./decel. curve selection, external frequency input bias start/end, jogging, retry after trip, restart after instantane, fuzzy accel/decel |
| |||||||||
|
Environment |
Ambient Temperature |
-10℃~50℃ / -20℃~65℃ |
| ||||||||
|
Ambient Humidity / Installation Area |
90%RH or less (No condensation) / indoors (no corrosive gases or dust) |
| |||||||||
|
Altitude |
Altitude 1,000m or less | ||||||||||